Search
Close this search box.

Level 2 Type 2 1000VDC PV DC Surge Protection Device

  • Place of use: Inverter, bus box
  • Protected mode:(DC+)-PE,(DC-)- PE,(DC+)-(DC-)
  • Surge rating:
    • Itotal=20 kA (8/20 μS)
    • Itotal= 40 kA(8/20 μs)
  • IEC/EN/UL Category: Level 2/ Type 2
  • Protecting component: High-energy MOV
  • Shell: Plug-and-dial design
  • Accord with a standard:
    • GB/T 18802-31
    • IEC 61643-31
    • EN 61643-31
,

Description

HCSPD1 series surge protectors belong to the DC side lightning arrester of the T2 PV system. When the system has overvoltage due to a lightning strike or other reasons, the protector immediately turns on in nanoseconds to introduce the overvoltage into the earth for discharge, so as to protect the equipment on the power grid.

They have reliable voltage protection levels, super surge discharge capacity and safety overload capacity, which are used for lightning protection of photovoltaic power generation systems.

The product is equipped with high-energy mov chip, so when the system has overvoltage due to lightning stroke or other reasons, it can introduce the voltage into the earth with nanosecond response speed, so as to protect the equipment.

IEC Electrical

Parameter Model 600 Model 1000 Model 1500
Structure U - Type Y - Type Y - Type
Maximum Continuous Operating Voltage (Ucpv) 600V 1000V 1500V
Nominal Discharge Current (PV In) 20kA 20kA 20kA
Maximum Discharge Current (Imax) 40kA 40kA 40kA
Voltage Protection Level (Up) 3.0kV 3.0kV 3.0kV
Response Time (T) ≤ 25ns ≤ 25ns ≤ 25ns
Degrees of Protection Provided by Enclosure IP20 IP20 IP20
Remote Signaling Contact (Optional) 11, 14 normally open;
11, 12 normally closed
11, 14 normally open;
11, 12 normally closed
11, 14 normally open;
11, 12 normally closed
Local Alarm Indication Normal green, fault red Normal green, fault red Normal green, fault red
Installation Method 35mm mounting rail 35mm mounting rail 35mm mounting rail

Mechanical & Environmental

Parameter Specification
Operating Temperature Range Ta -40 ºF to +158 ºF [-40 ºC to +70 ºC]
Permissible Operating Humidity RH 5%...95%
Atmospheric Pressure and Altitude 80 kPa ... 106 kPa / -500 m ... 2000 m
Terminal Screw Torque Mmax 39.9 lbf·in [4.5 Nm]
Conductor Cross Section (max) 2 AWG (Solid, Stranded)/ 4 AWG (Flexible)<br>35 mm² (Solid, Stranded)/ 25 mm² (Flexible)
Mounting 35 mm DIN Rail, EN 60715
Degree of Protection IP 20 (built-in)
Housing Material Thermoplastic: Extinguishing Degree UL 94 V-0
Thermal Protection Yes
Operating State / Fault Indication Green ok / Red defect
Remote Contacts (RC) Option Yes
RC Switching Capacity AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
RC Conductor Cross Section (max) 16 AWG (Solid)/ 1.5 mm² (Solid)

Downloads

Certification Files

Rated Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time

    Get Our Lastest Product Catalogue