1200W PV Micro inverter
- Single unit connects up to 4 PV modules
- Maximum 1200W AC output power
- Single phase output, Flexible 3-phase PV system
- WIFI communication and cloud monitoring
- Up to 4 units(230V) per branch
- Customizable various input (DV PV) voltage range
- Integrated AC bus cable, Ready-To-Use
- Low cost, Easy installation
,
Description
Single phase connection method of micro inverter
- HCMI1200 @Single-Phase 230V gridMaximum 4 units HCMI1200 Microinverters per branch.
- The max DC input power of each inverter is 1200W(the PV module max output power is 4x300W).
- The VOC of PV modules should not be greater than the max DC input voltage of Microinverters.
Technical Specifications
Model | HCMI-1200 |
Input Data (DC, PV) | |
Number of Input MC4 Connector | 4 sets |
MPPT Voltage Range | 22V-48V |
Operation Voltage Range | 18-60V |
Maximum Input Voltage | 52V |
Startup Voltage | 22V |
Maximum input power | 1200W |
Maximum input Current | 12A*4 |
Output Data(AC) | |
Single-Phase Grid Type | 120V&230V |
Rated Output Power | 1200W |
Maximum Output Power | 1200W |
Nominal Output Current | @120VAC:5A/@230VAC:2.6A |
Nominal Output Voltage | 120VAC /230VAC |
Default Output Voltage Range | @120VAC:90V-160V /@230VAC:190V-270V |
Nominal Output Frequency | 50Hz / 60Hz |
Default Output Frequency Range | @50Hz:48Hz-51Hz/@60Hz:58Hz-61Hz |
Power Factor | >99% |
Total Harmonic Distortion | THD <5% |
Maximum Units per Branch | @120VAC:2units /@230VAC: 4units |
Eifficiency | |
Nominal MPPT Efficiency | 99.5% |
Peak Efficiency | 95% |
Night Power Consumption | <1W |
Mechanical Data | |
Operating Ambient Temperature Range | -40°C to +65°C |
Storage Temperature Range | -40°C to +85C |
Dimensions (L × W × H) | 365mmx230mm x 40mm |
Weight | 3.5kg |
Max Current of AC Bus Cable | 20A |
Waterproof rating | IP65 |
Cooling Mode | Natural Convection- No Fans |
Other Features | |
Communication | WIFI(Cloud monitoring) |
Power transmission mode | Reverse transfer,load priority |
Monitoring System | Mobile APP, PC browser |
Transformer Design | High Frequency Transformers,Galvanically Isolated |
Integrated Ground | Equipment ground is provided by the PE in the AC cable. No additional ground is required. |
Protection Functions | lsolated Island Protection,Voltage Protection, Frequency Protection, Temperature Protection,Current Protection, etc. |
Design Compliance | EN IEC61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A1:2019+A2:2021, EN IEC55014-2:2021,EN IEC55014-2:2021 |
Certificate | CE |