350W PV Micro inverter

  • Single unit connects up to 1 PV module
  • Maximum 350W AC output power
  • Single phase output, Flexible 3-phase PV system
  • WIFI communication and cloud monitoring
  • Up to 10 units(230V) per branch
  • Customizable various input (DV PV) voltage range
  • Integrated AC bus cable, Ready-To-Use
SKU HCMI-350 Category Tag

Description

Single phase connection method of micro inverter

400W PV Micro Inverter 3

  • HCMI300 @Single-Phase 230V grid Maximum 10 units HCMI300 Microinverters per branch.
  • The max DC input power of each inverter is 300W(the PV module max output power is 300W).
  • The VOC of PV modules should not be greater than the max DC input voltage of Microinverters.

Technical Specifications

Model HCMI-350
Input Data (DC, PV)
Number of Input MC4 Connector 1 sets
MPPT Voltage Range 16V-48V
Operation Voltage Range 20-50V
Maximum Input Voltage 50V
Startup Voltage 18V
Maximum input power 350W
Maximum input Current 14A
Output Data(AC)
Single-Phase Grid Type 120V&230V
Rated Output Power 350W
Nominal Output Current @120VAC:2.5A/@230VAC:1.3A
Nominal Output Voltage 120VAC /230VAC
Default Output Voltage Range @120VAC:80V-160V /@230VAC: 180V-270V
Nominal Output Frequency 50Hz / 60Hz
Default Output Frequency Range @50Hz:48Hz-51Hz/@60Hz:58Hz-61Hz
Power Factor >0.99%
Total Harmonic Distortion THD <5%
Maximum Units per Branch @ 120VAC:5units /@230VAC: 10units
Eifficiency
Nominal MPPT Efficiency 99.50%
Peak Efficiency 95%
Night Power Consumption < 1W
Mechanical Data
Operating Ambient Temperature Range -40°C to +65°C
Storage Temperature Range -40°C to +85C
Dimensions (L × W × H) 195mmx185mm x 40mm
Weight 1.6kg
Max Current of AC Bus Cable 20A
Waterproof rating IP66
Cooling Mode Natural Convection- No Fans
Other Features
Communication WIFI(Cloud monitoring)
Monitoring System Mobile APP, PC browser
Transformer Design High Frequency Transformers,Galvanically Isolated
Integrated Ground Equipment ground is provided by the PE in the AC cable.
No additional ground is required.
Protection Functions Isolated Island Protection,Voltage Protection,
Frequency Protection,
Temperature Protection,Current Protection, etc.
Design Compliance EN IEC61000-3-2:2019+A1:2021,
EN 61000-3-3:2013+A1:2019+A2:2021,
EN IEC55014-2:2021,EN IEC55014-2:2021
Certificate CE

Downloads

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time

    Get Our Lastest Product Catalogue