Search
Close this search box.

1000Vdc 100-800A IR.50kA High Voltage Fast Acting Square Body Semicontactor Fuse

  • Volts: 1000Vdc
  • Amps: 100-800A
  • Interrupting Capacity:
    • Max 1000Vdc 50kA (or less)
    • Min ≥ 3In
  • Time Constant: ≤ 5ms
  • Class Type: aR
, , ,
SKU HCHVT1000-A-59E Category Tags , ,

Dimensions (mm)

HCHVT1000-A-59E

Description

  • Design For DC Applications
  • Excellent DC Performance
  • Low Watt Losses

Standards / Approvals

  • Refer To UL 248.1 / UL 248.13
  • IEC 60269.1 / IEC 60269.4
  • Reach Declaration Available Upon Request
  • UL, TUV
  • RoHS Compliant

Features & Benefits

  • Higher voltage rating provides overall system efficiency using smaller, more economical conductors while meeting the needs of higher voltage.
  • Up to ten times faster opening under high fault current conditions helps assure reliable protection of circuits and components.
  • Greater ampacity within sizing guidelines.
  • Excellent power of resisting voltaic impingement and environmental temperature tolerance.
  • Excellent resistance to mechanical vibration and impact resistance.

Fuse Ratings

Connect Part No. Fuse Amps Size Average @50KA/1000Vdc Power Loss (W) Approvals
 A²s Melting A²t Clearing 100% UL TUV
 Flush-end contact HCHVT1000-100A-59E 100A 2# 1,320 8,680 75
HCHVT1000-125A-59E 125A 2# 1,880 12,400 80
HCHVT1000-160A-59E 160A 2# 2,690 17,710 85
HCHVT1000-200A-59E 200A 2# 3,840 25,300 90
HCHVT1000-250A-59E 250A 2# 5,490 36,150 98
HCHVT1000-275A-59E 275A 2# 7,900 52,170 105
HCHVT1000-315A-59E 315A 2# 10,900 72,850 113
HCHVT1000-350A-59E 350A 2# 13,900 91,650 120
HCHVT1000-400A-59E 400A 2# 19,450 131,600 128
HCHVT1000-450A-59E 450A 2# 30,950 192,700 135
HCHVT1000-500A-59E 500A 2# 43,680 267,900 143
HCHVT1000-550A-59E 550A 2# 56,420 347,800 150
HCHVT1000-630A-59E 630A 2# 104,650 540,500 180
HCHVT1000-700A-59E 700A 2# 145,930 739,350 188
HCHVT1000-800A-59E 800A 2# 223,440 1,160,000 195
  • UL:E533379(100-400A);TUV:J50590371 (100-400A)
  • Application process to be determined
  • I²t 1000Vdc 50kA,T:<5ms;DC allows the maximum voltage:1048V

Applications

  • Electrical Energy Storage
  • Disconnector or Maintenance Safety Disconnect
  • Battery Pack Protection
  • Backup Protection For DC Relay

Downloads

Related Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time

    Download Our Full Catalog

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!