...
Search
Close this search box.

1500Vdc 100-1250A IR.250kA High Voltage Fast Acting Square Body Fuse 3# (without indicator)

  • Volts: 1500Vdc;
  • Amps: 100-1250A;
  • Interrupting Capacity:
    • Max 1500Vdc 250kA(or less);
    • Min BC ≥ 5In;
  • Time Constant: ≤ 5ms;
  • Class Type: aR;
, , , ,
SKU HCHVT1500-N-74E Category Tags , , , ,

Description

  • Higher voltage rating provides overall system efficiency using smaller, more economical conductors while meeting the need of higher voltage.
  • Up to ten times faster opening under high fault current conditions helps assure reliable protection of circuits and components.
  • Greater ampacity within sizing guidelines, excellent power of resisting voltaic impingement and environment temperature tolerance, excellent resistance to mechanical vibration and impact resistance.

CERTIFICATIONS

  • Refer To UL 248.1/UL 248.13
  • IEC 60269.1/IEC 60269.4
  • Reach Declaration Available Upon Request
  • CE
  • RoHS Compliant

Fuse Ratings

Connect Part No. Fuse Amps Average @250KA/1500Vdc Power Loss (W) Approvals
A²s Melting A²s Clearing 80% 100% UL TUV
Bolted HCHVT1500-100BN-74E 100A 1150 4680 48 60
HCHVT1500-125BN-74E 125A 1750 8350 52 68
HCHVT1500-160BN-74E 160A 3800 14000 68 90
HCHVT1500-200BN-74E 200A 5200 23500 82 110
HCHVT1500-250BN-74E 250A 10400 45000 92 120
HCHVT1500-315BN-74E 315A 21238 76760 104 136
HCHVT1500-350BN-74E 350A 29180 104691 113 148
HCHVT1500-400BN-74E 400A 38468 136083 130 171
HCHVT1500-450BN-74E 450A 54749 192815 143 187
HCHVT1500-500BN-74E 500A 74371 259379 155 204
HCHVT1500-550BN-74E 550A 93073 317075 169 221
HCHVT1500-630BN-74E 630A 131578 437610 189 248
HCHVT1500-700BN-74E 700A 182476 593977 202 273
HCHVT1500-800BN-74E 800A 283377 893774 218 294
HCHVT1500-900BN-74E 900A 408596 1247411 237 305
HCHVT1500-1000BN-74E 1000A 546988 1605152 282 362
HCHVT1500-1100BN-74E 1100A 751540 2129888 300 385
HCHVT1500-1200BN-74E 1200A 991418 2779209 305 391
*HCHVT1500-1250BN-74E *1250A 1121162 3162024 314 401

○ Application process to be determined
* If there are any requirements, please communicate with the original factory staff first.

  • Bolted: xxxBN-74E
  • without fuse indicator
Connect Part No. Fuse Amps Average @250KA/1500Vdc Power Loss (W) Approvals
A²s Melting A²s Clearing 80% 100% UL TUV
Din HCHVT1500-100UN-74E 100A 1150 4680 48 60
HCHVT1500-125UN-74E 125A 1750 8350 52 68
HCHVT1500-160UN-74E 160A 3800 14000 68 90
HCHVT1500-200UN-74E 200A 5200 23500 82 110
HCHVT1500-250UN-74E 250A 10400 45000 92 120
HCHVT1500-315UN-74E 315A 21238 76760 104 136
HCHVT1500-350UN-74E 350A 29180 104691 113 148
HCHVT1500-400UN-74E 400A 38468 136083 130 171
HCHVT1500-450UN-74E 450A 54749 192815 143 187
HCHVT1500-500UN-74E 500A 74371 259379 155 204
HCHVT1500-550UN-74E 550A 93073 317075 169 221
HCHVT1500-630UN-74E 630A 131578 437610 189 248
HCHVT1500-700UN-74E 700A 182476 593977 202 273
HCHVT1500-800UN-74E 800A 283377 893774 218 294
HCHVT1500-900UN-74E 900A 408596 1247411 237 305
HCHVT1500-1000UN-74E 1000A 546988 1605152 282 362
HCHVT1500-1100UN-74E 1100A 751540 2129888 300 385
HCHVT1500-1200UN-74E 1200A 991418 2779209 305 391
*HCHVT1500-1250UN-74E *1250A 1121162 3162024 314 401

● :UL:E533379  (100-800A);TUV:J50590376  (100-800A)
○ Application process to be determined
* If there are any requirements, please communicate with the original factory staff first.

  • Din: xxxUN-74E
  • without fuse indicator

Applications

  • ESS
  • Disconnector or Maintenance Safety Disconnect
  • Battery Pack Protection
  • Backup Protection For DC Relay

Downloads

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time

    Get Our Lastest Product Catalogue