1500Vdc 100-400A IR.250kA High Voltage Fast Acting Square Body Fuse 2#

  • Volts: 1500Vdc;
  • Amps: 100-400A;
  • Interrupting Capacity:
    • Max 1500Vdc 250kA(or less);
    • Min BC ≥ 5In;
  • Time Constant: ≤ 5ms;
  • Class Type: aR;
, , , ,
SKU HCHVT1500-N-59E Category Tags , , , ,

Description

  • Higher voltage rating provides overall system efficiency using smaller, more economical conductors while meeting the need of higher voltage.
  • Up to ten times faster opening under high fault current conditions helps assure reliable protection of circuits and components.
  • Greater ampacity within sizing guidelines, excellent power of resisting voltaic impingement and environment temperature tolerance, excellent resistance to mechanical vibration and impact resistance.

CERTIFICATIONS

  • Refer To UL 248.1/UL 248.13
  • IEC 60269.1/IEC 60269.4 
  • UL, TUV
  • RoHS Compliant

Fuse Ratings

Connect Part No. Fuse Amps Average @250KA/1500Vdc Power Loss (W) Approvals
A²s Melting A²t Clearing 80% 100% UL TUV
Bolted HCHVT1500-100BN-59E 100A 3085 8568 43 55
HCHVT1500-125BN-59E 125A 4746 13182 47 60
HCHVT1500-160BN-59E 160A 7415 20597 53 68
HCHVT1500-200BN-59E 200A 11547 31208 69 86
HCHVT1500-250BN-59E 250A 18720 50594 86 108
HCHVT1500-315BN-59E 315A 31897 86207 102 128
HCHVT1500-350BN-59E 350A 42423 114556 110 137
HCHVT1500-400BN-59E 400A 61039 164970 122 153
  • DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃;
  • UL:E533379(100-400A);TUV:J50590371 (100-400A)
  • Bolted: xxxBN-59E
  • without fuse indicator
Connect Part No. Fuse Amps Average @250KA/1500Vdc Power Loss (W) Approvals
A²s Melting A²t Clearing 80% 100% UL TUV
Din HCHVT1500-100UN-59E 100A 3085 8568 43 55
HCHVT1500-125UN-59E 125A 4746 13182 47 60
HCHVT1500-160UN-59E 160A 7415 20597 53 68
HCHVT1500-200UN-59E 200A 11547 31208 69 86
HCHVT1500-250UN-59E 250A 18720 50594 86 108
HCHVT1500-315UN-59E 315A 31897 86207 102 128
HCHVT1500-350UN-59E 350A 42423 114556 110 137
HCHVT1500-400UN-59E 400A 61039 164970 122 153
  • DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃;
  • UL:E533379(100-400A);TUV:J50590371 (100-400A)
  • Din: xxxUN-59E
  • without fuse indicator

Applications

  • ESS
  • Disconnector or Maintenance Safety Disconnect
  • Battery Pack Protection
  • Backup Protection For DC Relay

Downloads

Rated Products

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 20

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    HIITIO logo full 300

    Talk to us now

    What products are you interested in?
    Just in case we can't get back to you in time

    Get Our Lastest Product Catalogue